How To Reset A Service Code On A Mcz Pellet Stove
Loading knowledgebase suggestions...
Standard Alert Codes:
A01 Burn failed to ignite
Cheque the pellet level in the tank.
Bank check whether the brazier is correctly seated and does not have whatsoever axiomatic incrustations of noncombusted fuel;
Bank check whether the pellet igniter heats up.
A02 Abnormal fire extinguishing
Results from burn extinguishing due to lack of fuel
(tank empty).
A03 The pellet tank prophylactic device has been triggered.
Overheating has been detected, caused by a malfunction or an overload of fuel
Check the parameters of the recipe used
The boiler was used at maximum performance for as well long.
A08 Smoke blower fan faulty
Bank check that the fume blower fan is clean to ensure that no clay is clogging it.
If this does non solve the problem the fume blower is faulty. Call an authorised service centre to have the fan replaced.
A10 The pellet igniter is faulty
Contact an authorised service centre to have the component replaced.
A11 Fault in the geared motor of the pellet feed
Contact an authorised service centre to have the component replaced.
A13 Electronic board fault
This alert is triggered if the board does not communicate with its peripherals (cables poorly connected) or if there is a mistake in the electronic board.
Contact a service heart to have the component replaced.
A18 Temperature of the water tank besides high
This alert is triggered if the water inside the organization does not circulate and the safety temperature (95°) and humid temperature rise.
Check the pump and release it if it has shut down.
Bank check whether there are closed cut-off cocks.
Service: Regular maintenance advice
If this message appears at beginning-up, this ways that the preset operating time before maintenance has expired and maintenance is due to be carried out. Contact a qualified technician.
Previous Version Controller:
DEP Neglect Smoke outlet pipe obstructed or back-pressure acquired by wind outside.
Bank check and clean the ENTIRE smoke duct or check whether the exterior wind prevents the fume from exiting.
Just once the cause of the shutdown has been permanently remedied can the stove be restarted.
ALAR FAN Neglect Smoke blower fan speed too low or fan off
The smoke blower fan is blocked past a foreign body.
The fan is broken.
Check how make clean the fan is and whether dirt is slowing it down.
If the problem is not solved through cleaning, replace the smoke blower fan
Cheque that the encoder cable is connected correctly
ALAR SOND FUMI The fume sensor is damaged.
Supplant the smoke sensor
ALAR SIC Neglect The safety device that controls the pellet tank or the temperature of the water in the boiler has
been triggered.
Overheating has been detected, caused by a malfunction or an overload of fuel
Cheque the parameters of the recipe used
Bank check whether in that location are airtight cut-off cocks.
The banality was used at maximum performance for too long.
ALAR HOT TEMP The temperature of the smoke reaches and remains above the set parameters for too long.
Clean the inside of the exchanger and operate the boiler at maximum operation for shorter periods of time.
Also cheque the quality of pellets.
ALAR NO ACC Kickoff failed start-upwardly endeavor.
If this was the first start-up and the tank was empty, repeat the commencement-up process or check the level of pellets in the tank.
Bank check the pellet igniter.
ALAR NO Burn Banality shuts downwards and when the fume sensor temperature is below the set threshold.
It is due to the flame dying out due to bottleneck or when the pellets in the tank take run out.
Attachments:
MCZ_RED_Fault_Codes.pdf
Was this commodity helpful? yeah / no